S890QL
Data verifiedS890QL is the EN 10025-6 Q&T structural plate with 890 MPa minimum yield — a step beyond S690QL for boom and chassis designs where every kilogram of dead weight costs payload. It uses the same lean ladle chemistry envelope as the whole S460–S960 family; strength comes from the quench-and-temper practice.
Chemical composition
| Element | Content (%) |
|---|---|
| C | ≤0.20 |
| Si | ≤0.80 |
| Mn | ≤1.70 |
| P | ≤0.020 |
| S | ≤0.010 |
| Cr | ≤1.50 |
| Ni | ≤2.00 |
| Mo | ≤0.70 |
| B | ≤0.005 |
Weight percent, per the governing standard ranges. Actual values per heat are on the mill certificate.
Properties
| Yield strength | ≥890 MPa (≤50 mm) |
| Tensile strength | 940–1100 MPa |
| Impact | QL: 27 J at −40 °C |
| Density | 7.85 g/cm³ |
Heat treatment
Delivered quenched and tempered. Post-weld heat treatment is generally not permitted above the mill tempering temperature.
Equivalent grades
| Standard | Designation |
|---|---|
| din | S890QL (EN 10025-6) |
| gb | Q890 (GB/T 16270, near) |
Compare side by side: S890QL vs S960QL · S890QL vs S690QL
Equivalents overlap in chemistry and use but are not always identical — see our equivalents guide before substituting in certified designs.
Applications & Processing
Applications: Telescopic crane booms, aerial work platforms, heavy trailer chassis, mining equipment structures.
Processing: Demanding fabrication: matching high-strength consumables, narrow preheat/interpass windows, strict heat-input limits. No flame straightening without procedure approval.
FAQ
- S890QL vs S690QL?
- Same chemistry philosophy and −40 °C QL toughness; S890QL guarantees 890 MPa yield vs 690 MPa. Designs can shed roughly 20% section weight, but weld procedure qualification and consumable cost rise sharply.
Need S890QL from stock?
Steel.Wiki is sponsored by Shenzhen NewAsia Special Steel (Nasteel), a special-steel stockholder in Shenzhen stocking mold, tool and alloy steels with EN 10204 3.1 certification.
Ask for a quotationVisit NasteelSource: EN 10025-6 published ranges · Last updated 2026-11-03. Data is indicative — verify critical values against the governing standard and mill certificate before use.